5-12
Message Cause Solution
The value of the negative pressure sen-
sor is abnormal.
• Perform “PRESSURE ADJUST” ( P.5-
9) of the maintenance. If you cannot
adjust it to the normal value, or, even if
you perform, it may be displayed, contact
your local distributor to call for service.
The value of the positive pressure sen-
sor is abnormal.
The ink of the ink bottle has been nearly
used up.
• Press the key to check the rele-
vant ink bottle. Be careful because it may
be INK NEAR END soon.
Ink could not be supplied to the sub
tank.
• Perform “SUB TANK” ( P.5-5) of the
maintenance. Also check the remaining
amount of ink in the ink bottle. Even if you
performed this, when the message is dis-
played, contact your local distributor to
call for service.
The liquid level sensor abnormality of
the sub tank has been detected.
• Turn off the power to the machine and
turn it on after a while.
• If the same error message appears again,
contact your local distributor to call for ser-
vice.
Overflow from the sub tank has been
detected.
• Perform “SUB TANK” ( P.5-6) of the
maintenance. Even if you performed this,
when the message is displayed, contact
your local distributor to call for service.
Though a certain amount was con-
sumed, there is no change in the sub
tank sensor High.
Though a certain amount was con-
sumed, there is no change in the sub
tank sensor Low.
The deaeration module in the ink path
shall be replaced soon.
(One year has passed since you started
using it.)
• The deaeration module shall be replaced.
Contact a distributor in your district, our
office, or our call center.
The machine temperature is high.
Adjust the ambient temperature of the
installation place.
The machine temperature is low.
Time to clean the Y motor has come.
• Turn off the power and vacuum debris of
the Y motor from the vacuuming window.
( P.4-31)
• After the replacement, press the
key on the local screen to clear
the warning.
Time to replace the brush of Y motor
has come.
• The brush of Y motor shall be replaced.
Contact a distributor in your district, our
office, or our call center.
Time to replace the carriage filter has
come.
• Replace the carriage filter referring to the
separate “Requests for Daily Care and
Maintenance”.
Time to replace the UV fan filter has
come.
• Replace the carriage filter referring to the
separate “Procedure Manual to replace
UV FAN Filter”.
It has elapsed 7days or more after the
water in the cooling water tank was
reduced.
• Replenish the cooling water to the cooling
water tank whose tank number is dis-
played.
While this warning is displayed, the online
print can not be made.
< LOCA L >
NEGAT I VE PRESSURE
< LOCA L >
POS I T I VE PRESSURE
< LOCA L >
I NK NEAR END [ ENT ]
< LOCA L >
SUPPLY I NK :MMCCYYKK
< LOCA L >
Su b t an kSen s : MMCCYYKK
< LOCA L >
I n kOv e r f l ow : MMCCYYKK
< LOCA L >
TANK l e v r l H : MMCCYYKK
< LOCA L >
TANK l e v r l L : MMCCYYKK
<LOCAL>
Rep l ace DegassModu l e
< LOCA L >
Ma c h i n e TEMP / H i * * *
°
C
< LOCA L >
Mach i neTEMP/ Lo * * *
°
C
< LOCA L >
Ymo t or Cl ean i ng [MNT]