EasyManua.ls Logo

MIMAKI JFX500-2131 - Page 129

MIMAKI JFX500-2131
156 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Warning / Error Messages
5-15
1
1
1
1
5
Troubleshooting
Message Cause Solution
COM driver becomes the high tempera-
ture.
Turn off the power to the machine and
turn it on after a while.
If the same error message appears again,
contact your local distributor to call for ser-
vice.
New Print Head was recognized.
The main PCB Q6 is disabled (short
mode).
An error is detected on the waveform
printed on.
An error occurred in the main PCB
VCORE power supply.
An error occurred in the main PCB 1.5V
power supply.
An error occurred in the main PCB 12V
power supply.
Abnormality of the flushing control.
Abnormality of the head voltage control.
Abnormality of the HDC substrate volt-
age.
The LED UV is not connected.
The machine received some data other
than command data.
Securely connect the interface cable in
position.
Use an interface cable conforming to the
specifications.
Any parameter outside the range of
acceptable numeric values was
received.
A maintenance command error
occurred.
ERROR1 5 f
HEAD DR I VE HOT
ERROR 171
NEW HEAD CONNECT
ERROR 172
Ma i n PCB Q6 Ch e c k K
ERROR 186
HDC OVERF LOW
ERROR 186
HDC UNDERF LOW
ERROR 187
HDC S L EW RATE
ERROR 188
HDC MEMORY
ERROR 18a
Ma i n PCB V_CORE
ERROR 18b
Ma i n PCB V1R5B
ERROR 1 8 c
Ha i n PCB V12
ERROR 18e
FLS NOT COMP [ 12__ ]
ERROR 1 8 f
OFFSET START [ 12__ ]
ERROR 1 8 f
OFFSET END [ 12__ ]
ERROR 19d
HDC V36 [ xxxx]
ERROR 1 9 F
LED CONNCT ERR
ERROR 201
COMMAND
ERROR 202
PARAMETER
ERROR 203
Me n t Comma n d

Table of Contents

Other manuals for MIMAKI JFX500-2131

Related product manuals