5-16
Message Cause Solution
USB device initialization failure.
• Turn off the main power to the machine
and turn it on after a while.
If the same error message appears again,
contact your local distributor to call for ser-
vice.
Occurrence of a time out error on a
USB device.
An excessive load was applied to the X
motor.
An excessive load was applied to the Y
motor.
An error due to an excessive current of
the X motor was detected.
An error due to an excessive current of
the Y motor was detected.
The media jam occurs. • Remove the media and reset it.
A HDC position counter error occurred.
• Turn off the main power to the machine
and turn it on after a while.
If the same error message appears again,
contact your local distributor to call for ser-
vice.
Y-origin could not be detected.
Abnormal Y linear scale.
The value of the negative pressure sen-
sor is abnormal.
• Perform “PRESSURE ADJUST” ( P.5-
9) of the maintenance. If you cannot
adjust it to the normal value, or, even if
you perform, it may be displayed, contact
your local distributor to call for service.
The value of the positive pressure sen-
sor is abnormal.
The X left-side linear scale has poor
sensitivity.
• Turn off the main power to the machine
and turn it on after a while.
If the same error message appears again,
contact your local distributor to call for ser-
vice.
The X right-side linear scale has poor
sensitivity.
The liquid level sensor abnormality of
the sub tank has been detected.
• Turn off the main power to the machine
and turn it on after a while.
If the same error message appears again,
contact your local distributor to call for ser-
vice.
Though a certain amount was con-
sumed, there is no change in the sub
tank sensor High.
• Perform “SUB TANK” ( P.5-5) of the
maintenance. Even if you performed this,
when the message is displayed, contact
your local distributor to call for service.
Though a certain amount was con-
sumed, there is no change in the sub
tank sensor Low.
Overflow from the sub tank has been
detected.
ERROR 3 0 4
USB I N I T ERR
ERROR 3 0 5
USB T I ME OUT
ERROR 4 0 1
MOTOR X
ERROR 4 0 2
MOTOR Y
ERROR 4 0 3
X CURRENT
ERROR 4 0 4
Y CURRENT
ERROR 5 0 5
MED I A J AM
ERROR 5 0 9
HDC POSCNT
ERROR 5 0 a
Y ORIGIN
ERROR 5 0 f
L - SCALE BLACK
ERROR 5 1 9
NEGAT I VE P . SENSOR
ERROR 5 1 a
POS I T I VE P . SENSOR
ERROR 5 1 e
PL ENC SNS ( L )
ERROR 5 1 e
PL ENC SNS ( R )
ERROR 6 1 7
SUBTANK SNN: 12345678
ERROR 6 1 8
TANK l eve lH : 12345678
ERROR 6 1 9
TANK l eve l L : 12345678
ERROR 6 1 a
OVER FLOW : 12345678