141
Error
numbe
r
Message Cause Corrective action
0312 CMD ERROR MAIN-PE FW
communication error An
error was detected for the
command.
Turn off the control PC, then turn off
the main power. Wait briefly before
turning the control PC and the main
power back on.
0313 CMD TIMEOUT MAIN-PE FW
communication error An
error was detected for the
command.
0314 NOTICE ERROR MAIN-PE FW
communication error
Notifications cannot be
received from PE-FW.
0401 MOTOR X The X motor was
overloaded.
0402 MOTOR Y The Y motor was
overloaded.
0403 X CURRENT An overcurrent was
detected in the X motor.
0404 Y CURRENT An overcurrent was
detected in the Y motor.
0406 WIPER ORG The wiper origin could not
be detected.
0505 MEDIA JAM The media jam sensor
was triggered.
1. Remove the media in contact with the
carriage and reload with fresh media.
2. Clear the alarm on the touch panel.
"Clearing Alarms"(P. 99)
0506 STATION SENS The station sensor could
not be detected.
Turn off the control PC, then turn off
the main power. Wait briefly before
turning the control PC and the main
power back on.
0509 HDC POSCNT A problem was detected
with position control.
050A Y ORIGIN A problem was detected
with Y origin detection
(initialization).
050F L-SCALE BLACK A problem was detected
with the linear scale.
0510 X ORIGIN A problem was detected
with X origin detection
(initialization).
0511 Z ORIGIN A problem was detected
with Z origin detection
(initialization).
0512 CAPSHTR ORIGIN Shutter sensor read
failure.
0515 DETECTION ERROR Cap pin detection sensor
read failure.
0519 NEGATIVE PRESS
SENSOR
Negative pressure sensor
problem detected
Adjust the pressure. "A pressure
error occurred."(P. 135)