EasyManua.ls Logo

MIMAKI JFX550-2513 - Page 142

MIMAKI JFX550-2513
164 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 5 Troubleshooting
142
Error
numbe
r
Message Cause Corrective action
051A POSITIVE PRESS
SENSOR
Positive pressure sensor
problem detected.
0525 WRONG IONIZER The ionizer internal circuit
is defective, or an
abnormal discharge
occurred.
Turn off the control PC, then turn off
the main power. Wait briefly before
turning the control PC and the main
power back on.
0526 IONIZER ION LEVEL The amount of generated
ions was reduced due to
fouling and abrasion of the
electrode needle.
Refer to the instruction manual for
the ionizer and clean the electrodes.
If this error continues to be displayed
after cleaning, contact your local
dealer or our service office.
0527 IONIZER CONDITION Ambient conditions may
cause ions to be absorbed
by metals in the vicinity
and affect discharge
capability.
Please check for any metallic objects
in the vicinity of the ionizer. Be sure
to remove any metallic objects that
are found. If this error continues to be
displayed after removing such
objects, contact your local dealer or
our service office.
0542 EMERGENCY SW The emergency stop
switch was pressed.
1. Resolve the cause of this problem.
2. Turn the emergency stop switch to
unlock.
3. Clear the alarm on the touch panel.
"Clearing Alarms"(P. 99)
Clearing the alarm will start the
initial operations.
054A PDC POSINT:1234 No PDC position interrupt
is generated. A problem
occurred with the linear
encoder scale or the Y
motor.
Turn off the control PC, then turn off
the main power. Wait briefly before
turning the control PC and the main
power back on.
0556 Y LIMIT SENSOR The carriage has
exceeded the operating
range in the Y direction.
Contact your local dealer or our
service office.
0557 OBSTACLE
DETECTION
The light curtain was
triggered.
1. Remove the obstacle from the light
curtain detection area. "Light
curtain"(P. 38)
2. Clear the alarm on the touch panel.
"Clearing Alarms"(P. 99)
0558 PDC SCANPOS No main FW PDC position
interrupt is generated. A
problem occurred with the
Y motor.
Turn off the control PC, then turn off
the main power. Wait briefly before
turning the control PC and the main
power back on.
0601 INK NEAR END Ink levels are low. The ink will run out soon. Have new
ink ready. "When Ink Near End is
Displayed"(P. 49)
0602 INK END The ink has run out. Replace with new ink. "When Ink
End is Displayed"(P. 49)
"Replacing Ink"(P. 50)
0604 WASTE INK TANK
NEAR FULL
The waste ink tank is
nearly full.
Note that the waste ink tank will be