Chapter 5 Troubleshooting
143
Error
numbe
r
Message Cause Corrective action
0605 REPLACE WIPER • It is time to replace the
wiper.
1. Replace the wiper. "Wiper
Replacement"(P. 123)
2. Clear the alarm on the touch panel.
"Clearing Alarms"(P. 99)
0606 WRONG INK IC • The ink IC chip cannot be
read correctly.
1. Reinsert the ink IC chip.
2. Clear the alarm on the touch panel.
"Clearing Alarms"(P. 99)
3. If this error continues to be displayed
after restarting, insert the supplied ink IC
into the new ink bottle.
060C INK TYPE ERROR • The ink type registered on
the IC chip differs from the
ink type filled.
1. Insert an ink IC chip for the correct ink
type.
2. Clear the alarm on the touch panel.
"Clearing Alarms"(P. 99)
060F INK EXPIRATION • The ink has expired. • Replace with new ink or use up as
quickly as possible. Printing is
possible. "Replacing Ink"(P. 50)
• If this message is displayed when
inserting an ink IC chip into an ink
bottle that has not reached its
expiration date, contact your local
dealer or our service office.
0610 NOT FILLUP • Ink filling is not complete. • Contact your local dealer or our
service office.
0617 WRONG SUBTANK
SENSOR
• A sub-tank fluid level
sensor error was
detected.
• Turn off the control PC, then turn off
the main power. Wait briefly before
turning the control PC and the main
power back on.
061A INK OVERFLOW • Sub-tank sensor limit
detected
1. Execute [MAINTENANCE] > [Other
maintenance] > [Sub-tank maintenance].
2. Clear the alarm on the touch panel.
"Clearing Alarms"(P. 99)
061B INK SUPPLY • Ink cannot be supplied to
the sub-tank.
1. Execute [MAINTENANCE] > [Other
maintenance] > [Sub-tank maintenance].
2. Clear the alarm on the touch panel.
"Clearing Alarms"(P. 99)
3. If this error continues to be displayed
after clearing, turn off the control PC,
then turn off the main power. Wait briefly
before turning the control PC and the
main power back on.
4. Execute [MAINTENANCE] > [Other
maintenance] > [Sub-tank maintenance].
061C NEGATIVE PRESS
CONTROL
• Negative pressure control
could not be initiated.
1. Execute [MAINTENANCE] > [Other
maintenance] > [Adjust negative
pressure]. "A pressure error
occurred."(P. 135)
2. Clear the alarm on the touch panel.
"Clearing Alarms"(P. 99)
3. After the function has finished, reapply
the negative pressure.
061D NEGATIVE PRESS
NOT ENOUGH
• Proper negative pressure
cannot be maintained.
061E NEGATIVE PRESS
OVER
• Excessive negative
pressure
5