EasyManua.ls Logo

MIMAKI JV300-130 - 2.3 Circuit Board Specifications

MIMAKI JV300-130
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
© 2014 MIMAKI ENGINEERING CO.,LTD. 5.1 P.6
5.1 Changing the Joints
R.1.0
1
2
3
4
5
6
7
6. Remove cartridge rear cover from the back panel of the main
unit.
7. Release the knob of fittingφ2, and remove the fitting assy for
UISS.
8. Attach the F seal rubber 300 removed in the procedure 6 and
the new Fitting to the 3-ways fitting.
Cartridge rear cover
Release Release
F seal rubber 300
Fitting
Fitting assy
for UISS
3-ways fitting
Pay attention not to lose the F seal rubber 300.
3-ways fitting
F seal rubber 300
Fitting
Cap-outer
Attach it so that the step of F seal rubber 300 is at
the side of the 3-ways fitting.
INSTALLATION GUIDE > Ink Set > Changing the Joints
Model
JV300
Issue
2014.04.11
Revised F/W ver.
1.00
Remark
1.0
Rev.

Other manuals for MIMAKI JV300-130

Related product manuals