© 2014 MIMAKI ENGINEERING CO.,LTD. 7.4 P.13
7.4 Dot Position Adjustment (Service mode)
R.1.0
1
2
3
4
5
6
7
19. Check and compensate the patterns.
The reference lines are drawn in going, and then the adjustment
lines are drawn at the same Y-coordinate positions in returning.
The position where the lines above are overlapped on one
vertical line is specified as the correct dot position (H1A: M-
color fixed)
Confirm that the dots are on the same line.
* The adjusting procedure is the same although the drawing
pattern is different depending on mode.
[]/[] : Compensating value input (Measured value)
[ENTER] : Confirms
20. When compensated, draw and check the patterns again.
540Std BiDir WF3
= 0.0
-50.0~50.0
Check if the displacement
is almost equal in the right,
the center and the left of the
drawn area.
If the displacement is significantly different in the
right and left, other reasons are considered.
Repeat “Drawing -> Checking (Compensating)” until
any compensation is not required.
INSTALLATION GUIDE > Outputting Plots > Dot Position Adjustment (Service mode)
Model
JV300
Issue
2014.04.11
Revised F/W ver.
1.00
Remark