© 2011 MIMAKI ENGINEERING CO.,LTD. 6.4.9 P.1
1
2
3
4
5
6
7
8
6.4.9 X Motor Junction FFC 180 (1) and 180 (2)
Work procedures
1. Remove the following covers.
• Y cover R
• ICU cover R
• Wiring cover
• Power unit box cover
2. Remove the block core.
3. Unlock the connector, and pull and remove the X motor junc-
tion FFC 180 (1) and 180 (2).
Turn the main power OFF when turning the power OFF.
It is very dangerous if sleep mode functions mistakenly during the operation.
R.1.0
MAINTENANCE MANUAL > Disassembly and Reassembly > Electrical Parts > X Motor Junction FFC 180 (1) and 180 (2)