Chapter5 Troubleshooting
5-9
1
2
2
2
5
6
Ink Expiration Over M_ _ _ _ _ _
_
The ink has expired (less than 2 months
from expiration).
• Replace the ink pack or 10kg ink tank and
ink IC chip.
(It can be used from the expiration date up to
2 months.)
Replace the Spout Rubber of
Eco cartridge
Spout rubber of eco-case is time to
replace
• Replace the spout rubber of the eco case.
!Ink Remaining
Need to check because the remaining
amount of the tank has become a little
left. (The remaining ink level in the tank
is less than 25%.)
• Perform ink level correction as necessary.
!WashLiquidCart.None
Maintenance washing liquid cartridge is
not set.
• Set the maintenance washing liquid car-
tridge.
!Wash Liquid End
Maintenance washing liquid cartridge is
empty.
• Replace with a new maintenance washing
liquid cartridge.
!Machine TEMP./H ** °C
The ambient temperature is higher than
the usable temperature of the equip-
ment.
• Adjust the room temperature to the usable
temperature (20°C - 30 °C) because there is
a possibility that normal print results may not
be obtained due to adverse effects on ink
discharge.
!Machine Temp./l ** °C
The ambient temperature is lower than
the usable temperature of the machine.
!Connect 10kg Supply Unit The 10kg supply unit is not connected.
• Restart the unit.
If displaying again, contact your local distrib-
utor, our sales office, or service center.
Take-up LimitDetect
The upper limit of the take-up tension
bar position is detected.
• Lower the take-up tension bar.
Feeding LimitDetect
The upper limit of the feeding tension bar
position is detected.
• Lower the feeding tension bar.
Take-up Wrong
The take-up tension bar is not moving
from the lower limit position.
• Check that the take-up unit works properly
with the jog key.
Feeding Wrong
The feeding tension bar is not moving
from the lower limit position.
• Check that the feeding unit works properly
with the jog key.
Take-up CoverOpen The cover of the take-up unit is open. • Close the cover of the take-up unit.
Feeding CoverOpen The cover of the feeding unit is open. • Close the cover of the feeding unit.
Take-up Connect
The connection between take-up and
feeding is reversed.
• Restart the unit.
If displaying again, contact your local distrib-
utor, our sales office, or service center.
Invalid Operation
Feeding Connect
The connection between take-up and
feeding is reversed.
Take-up Unit None The take-up unit is not connected.
Feeding Unit None The Feeding unit is not connected.
Take-up EmerSW On
The emergency stop switch of the take-
up unit is pushed.
• Release the emergency stop switch of the
take-up unit.
Feeding EmerSW On
The emergency stop switch of the feed-
ing unit is pushed.
• Release the emergency stop switch of the
feeding unit.
Take-up Unit Power
The normal state of the inverter of the
take-up unit cannot be confirmed.
• Restart the unit and check that the inverter
power supply of the take-up unit is in normal
condition.
Feeding Unit Power
The normal state of the inverter of the
feeding unit cannot be confirmed.
• Restart the unit and check that the inverter
power supply of the feeding unit is in normal
condition.
Take-up Relay Welding
There is a possibility that the relay of the
take-up unit is broken.
• Restart the unit.
If displaying again, contact your local distrib-
utor, our sales office, or service center.
Feeding Relay Welding
There is a possibility that the relay of the
feeding unit is broken.
Replace Wiper
The used count of wiper has exceeded
the specified number.
• Execute maintenance, station maint.?and
replace wiper to replace the wiper.
Display Cause Measures