When Nozzle Clogging Cannot Be Solved
4-23
1
1
1
4
Routine Maintenance
5
Press to select the Nozzle line that needs
NOZZLE RECOVERY and press the key.
6
Register the Nozzle number that needs NOZZLE
RECOVERY and press the key.
(1)
Select the registration number from 1 to 10 by pressing
and press the key.
(2) Register the nozzle number that needs recovery by pressing
and press the key.
• If the registered nozzle cannot be recovered, the screen of
the Step 3 in P.4-24 “Check the print condition for which
nozzle recovery cannot be performed” is displayed.
7
Press the key several times to end the setting.
• Up to 10 nozzles can be registered per 1 nozzle line.
• Even if you use this function, time required for drawing does not change.
• For the lowest number of paths of the drawing mode, the NOZZLE RECOVERY function is invalid.
• Even if you register the NOZZLE RECOVERY, the pattern of test print etc. is not recovered.
Nozzle missing
No.184
Nozzle
number
Nozzle missing
No.16
Nozzle missing
No.128
Registration
number
Recovery
Nozzle No.
State
116
Target for nozzle recovery
2 128
Target for nozzle recovery
3 184
Target for nozzle recovery
4 OFF
No registration
5OFF
No registration
Example of nozzle to be recovered