5-10
Chapter 5 Troubleshooting
REFILL WATER Water in the cooling water tank is insufficient.
Replenish the antifreeze mixed water.
(P.4-27)
WATER LACK
It has passed more than seven days after water
in the cooling water tank become low.
Replenish the antifreeze mixed water.
(P.4-27)
While displaying this warning, you will not be
able to print.
Take-UP CoverOPEN
It was detected that the media take-up device's
cover was open.
Close the take-up device's cover.
Take-UP WRONG
An abnormality occurred in the take-up status of
the media take-up machine.
Check if the media setting is set to ROLL
when the take-up device is not used.
Check if the taking-up direction switch and the
taking-up manual switch are set correctly.
( P.2-6,P.2-7)
Check that the media is set on the media take-
up machine correctly.
Check if the media take-up paper core is run-
ning without load.
Turn ON and OFF the manual switch, and
raise the tension bar to a correct position.
Feed the media in the jog operation in the
direction reverse to that used at the time when
the error occurred.
Take-UP LimitDETECT
The control limit sensor of the media take-up
machine was detected.
Check if the media can be fed correctly in the
jog operation.
Lower the position of the tension bar at the
take-up side.
Even if you perform, if the same message is
displayed, contact a distributor in your district,
our office or our call center.
TAKE-UP ENC WRONG An abnormality occurred in the take-up encoder. Turn off the main power to the machine and
turn it on after a while ( P.2-3).
Even if you perform, if the same message is
displayed, contact a distributor in your district,
our office or our call center.
Take-UP Connect The take-up unit is not correctly connected.
Take-UP Fuse Err The take-up fuse is blown.
TAKE-UP TENSION-BAR
The media set check at the start of printing
detected an abnormality of the take-up tension
bar.
Check the media set condition and remove
any cause of the problem.
Check that the taking-up direction switch is set
correctly. ( P.2-6)
Take-UP Voltage
An abnormality occurred in the take-up unit volt-
age.
Turn off the main power to the machine and
turn it on after a while ( P.2-3).
Even if you perform, if the same message is
displayed, contact a distributor in your district,
our office or our call center.
Feeding CoverOPEN
It was detected that the media feeding device's
cover was open.
Check the cover of the feeding unit.
Even if you close the cover, if the same
message is displayed, contact a
distributor in your district, our office or our
call center.
Feeding WRONG
An abnormality occurred in the feeding status of
the media feeding machine.
Check if the media setting is set to ROLL
when the feeding device is not used.
Check if the taking-up direction switch and the
feeding manual switch are set correctly.
Check that the media is set on the media
feeding machine correctly.
Check if the media feeding paper core is run-
ning without load.
Turn ON and OFF the manual switch, and
raise the tension bar to a correct position.
Feed the media in the jog operation in the
direction reverse to that used at the time when
the error occurred.