Ex area
no ex area (secure area)
Screen
Cable junction box
External power supply SELV U
DC
= 24 V
Indicator
Potential equalization
5.2.1 Potential equalization
In order to avoid possible balancing currents between the individual conductive system
components, a potential equalization must be installed in potentially explosive areas.
The terminal must be connected to the potential equalization system and installed and
earthed in accordance with local regulations (see also schematic diagram).
Schematic diagram
(1)
(2) (1) (1) (2) (3)
(6) (6)
(A)
(4)
(4) (4)
(A) (A) (A) (A) (A) (A)
(E)
(5)
(B)
(1)(1)(1)(1)(1)
(A) (A) (A) (A)
1
2
4
3 3
Potentially explosive atmosphere
Non-potentially explosive atmosphere
Load cell
Cable junction box
Intrinsically safe load Cell interfaces PR 1626/60, ../61 5 Installation