6 Maintenance/repairs
6.1 Maintenance
Maintenance work may only be carried out by a trained technician with expert knowledge
of the hazards involved and the required precautions.
National laws and directives must be observed, in particular EN 60079-14/-17/-25.
6.2 Repairs
Repairs are subject to inspection and must be carried out at Minebea Intec.
In case of defect or malfunction, please contact your local Minebea Intec dealer or service
center for repair.
When returning the device for repair, please include a precise and complete description of
the problem.
WARNING
Possible explosion due to improper replacement!
It is not permissible to change fuses in Ex devices!
Intrinsically safe load Cell interfaces PR 1626/60, ../61 6 Maintenance/repairs
EN-16 Minebea Intec