Sequence of net discharge with lling signals "coarse/ne"
Taring:
The current weight is saved as the tare and
the net weight starts at zero.
Coarse:
A coarse ow (coarse and ne) is batched
until the preset value is reached.
Fine:
A ne ow is batched until the switch-o
point (overshoot) is reached.
Calming:
Wait time during which the overshoot is ef-
fective and scale vibrations may settle.
Tolerance Checking:
The weight is determined and checked
against the tolerance values.
8.3.1.3 Interaction mode
You can choose between the following control/operating modes of the device in
production:
- [Remote proc. control] via OPC/ModBus and/or eldbus
- [VNC] (Virtual Network Computing)
The following table shows how individual modes are locked when production starts.
Starting production
Mode VNC Remote control
OPC/ModBus
Remote control
eldbus
Digital inputs Digital out-
puts
[Remote proc.
control]
[VNC]
8.3.2 Conguring digital inputs and outputs
SPM addresses are assigned to the digital inputs and outputs under the [Conguration
digital IOs] menu item.
Note:
The selected SPM address must be unique within the system.
The SPM addresses for the input and outputs are unchanged after a restart.
Transmitter in eld housing PR 5230 8 Production