16.5 Error messages during calibration
Message Possible causes
This message displays, if the maximum load is too high.
The maximum load of the scale can be increased retroactively. When the
capacity is reduced, however, a message is displayed when the new ma-
ximum load is lower than the CAL weight ([Calibrated at]).
This message is displayed if the selected resolution is too low, e.g., 5 kg.
This message is displayed if the selected resolution is so high that less
than 0.8 internal counts per scale interval (d) and/or 0.5 µV/e are avai-
lable if legal-for-trade acc. to OIML/NSC.
This message displays if the maximum load is not an integer multiple of
the scale interval.
Weight units don't match, e.g., subsequent change for [Max] from kg in-
to lb.
16 Error messages Transmitter in eld housing PR 5230
EN-289 Minebea Intec