6.2.8.2 Configuring limits
1. Press and hold for 2–3 seconds.
SEtuP appears on the display.
2. Press "OK".
Cd 000 appears on the display (Cd flashes).
3. Press .
4. Select the individual parameters and modify if required, see Chapters
Parameter table (setup) and Selecting parameters.
[Limit 1 on] LI 030 LIM.1on
Input: Weight value under 1on.VAL
Selection: Action under 1on.ACt, see Chapter Defining actions
Selection: Condition under 1on.Cnd, see Chapter Setting conditions
[Limit 1 off] LI 031 LIM.1oF
Input: Weight value under 1oF.VAL
Selection: Action under 1oF.ACt, see Chapter Defining actions
Selection: Condition under 1oF.Cnd, see Chapter Setting conditions
[Limit 2 on] LI 032 LIM.2on
Input: Weight value under 2on.VAL
Selection: Action under 2on.ACt, see Chapter Defining actions
Selection: Condition under 2on.Cnd, see Chapter Setting conditions
[Limit 2 off] LI 033 LIM.2oF
Input: Weight value under 2oF.VAL
Selection: Action under 2oF.ACt, see Chapter Defining actions
Selection: Condition under 2oF.Cnd, see Chapter Setting conditions
[Limit 3 on] LI 034 LIM.3on
Input: Weight value under 3on.VAL
Selection: Action under 3on.ACt, see Chapter Defining actions
Selection: Condition under 3on.Cnd, see Chapter Setting conditions