141
(3) Input data ZERO Same as
key
A/Z Same as
key
A/Z OFF Same as
key
HOLD HOLD the target selected by function F−10
LOCK Lock (prohibit) all key input
BCD−ENABLE Compulsive OFF for the related output with BCD
(High−impedance)
SEL.1、SEL.2 Selection of BCD output target.
Effective when BCD output target is changeover of the
external input (Setting of F−40:00002)
SEL.1
SEL.2 Output target
Open Open Gross weight
Short Open Part of A/Z cancel
Open Short Net weight
Short Short Gross weight
(4) Output target Change of Gross weight, Net weight and Change of external input can
be available with the related function F−40.
(5) Output times Changeable to 4 times/s, 20 times/s, 50 times/s or 100 times/s by
relative function F−46
9−2−3. Pin configurations for the BCD output connector
1 COM. 13 8×10
2
25 ERROR
2 1×10
0
14 1×10
3
26 P.C.
3 2×10
0
15 2×10
3
27 HOLD
4 4×10
0
16 4×10
3
28 LOCK
5 8×10
0
17 8×10
3
29 SEL.1
6 1×10
1
18 1×10
4
30 SEL.2
7 2×10
1
19 COM. 31 ZERO
8 4×10
1
20 2×10
4
32 A/Z
9 8×10
1
21 4×10
4
33 A/Z OFF
10 1×10
2
22 8×10
4
34 N.C.
11 2×10
2
23 POL. 35 BCD−ENABLE
12 4×10
2
24 OVR. 36 N.C.
Suitable plug : 57−30360 made by DDK
● Never connects with the N.C. pins.
● Never connects with the N.C. pins.
● An internal circuit and photocoupler are insulated.