45
Procedures
2
Press the key five times.
It makes the load display proceeded as
“FUNC”→“CCAL”→“ACAL” →“LCAL”
→“ZERO”→“SPAN”.
Here, set the maximum load that can be applied
within the maximum value on the load cell.
3
Press the key.
Span fine adjustment mode can be entered, then
the display on load display shows the present load
value and lights on and off. At the same time,
adjust the present load value to be the same load
applied on the load cell with the right keys.
By pressing the key continuously,
increment can be provided continuously.
The variation of load value for one push of
the right key is less than 1 digit of display.
Therefore, a few pushes of these keys are
required to get the change of 1 digit of
display value.
key :Span fine adjustment
display decreasing key
key :Span fine adjustment
display increasing key
4
Press the key.
The indication of load display will show “END”.