EasyManua.ls Logo

Minerva Experience M16 - Page 17

Minerva Experience M16
Print Icon
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
16
Problem and method of solving
Stoppage
Reason
Methods of solving
Indicator unlights
1. Power control plate power doesn’t
switch on
2. Power cut
1. Check rice cooker if unplug
2. Waiting
Heating plate unheat
1. Power control plate damaged
2. Fuse damaged
3. Heating plate damaged
Contact Repair Service Centre
Indicator lights heating plate
unheat
1. Heating plate damaged
2. Power control plate damaged
Contact Repair Service Centre
Rice under-cooked
1. Capacity of rice is much or less
1. Capacity of rice and water should
be adjusted, should be limited
between highest and lowest.
2. The proportion of water and rice
is not suitable.
2. Adjust the proportion of water and
rice.
3. Inner pot deformed
3. Turn round inner pot ,check sensor
of heating plate.
4. Something between inner pot and
heating plate
4. Cleanup the sundries.
5. Inner pot deformed
5. Send to Repair Service Centre or
buy a new one.
6. Main Power control plate damaged
6.Send to Repair Service Centre
7.Main temperature control machine
unusual
7. Send to Repair Service Centre
Rice Over Cooked
1. Inner pot deformed
1. Send to Repair Service Centre or
buy a new one.
2. Main Power control plate damaged
2. Send to Repair Service Centre
3. Main temperature control machine
unusual
3. Turn round inner pot, check sensor
of heating plate
Porridge Overflow
Capacity of porridge excessive
1. Adjusted the capacity
2. Installing the overflow proof lid.