D-34
(7) Removal of the Exposure Lamp
NOTE
Do not remove the Scanner positioning screws.
4002D264AB
Scanner mounting screws
Scanner positioning screws
4. Swing the Scanner counterclockwise and take it
out of the copier.
NOTE
At this point, the Scanner is kept connected to a flat
cable and cannot be taken off.
4002D102AB
5. Unplug one connector.
6. Remove two screws and the flat cable board.
7. Remove the Scanner.
4002D103AB
1. Remove the Scanner.
2. Unplug one connector from the Inverter Board.
3. Remove the harnesses from the corresponding
wiring saddles.
4002D105AF
4. Remove one screw and the Exposure Lamp.
4002D106AC