D-51
(3) Cleaning of the PC Drum Charge Corona Grid Mesh
NOTE
When handling the Comb Electrode, be sure to hold it
onto its both ends.
4002D147AB
10 mm 17 mm
6. Wipe clean the Housing with a soft cloth.
1139D177AA
1. Blow all foreign matter off the Grid Mesh with a
blower brush.
1136D195AA
NOTES
If the blower brush is not effective in cleaning seri-
ous contamination of the Grid Mesh, use a soft cloth
dampened with alcohol. At this time, place the Grid
Mesh on a flat surface and sweep the cloth along the
mesh.
After cleaning, use care not to touch the cleaned
Grid Mesh with bare hands.
1136D196AA