2-7. PC DRUM CHARGE CORONA/IMAGE TRANSFER CORONA UNIT
(1) Cleaning of the PC Drum Charge Corona Housing
1. Remove the Imaging Unit.
2. Remove the PC Drum Charge Corona Unit.
3. Press the Mesh Holder on the front of the Corona Unit
in the direction of the arrow to remove the Grid Mesh.
4. Remove the Cleaning Pad Cover.
5. Remove the End Caps from the front and rear ends of
the Unit.
6. Remove the Comb Electrode.
Use care not to deform the Electrode. When
removing it, first snap off its spring end.
NOTE
(2) Cleaning of the PC Drum Charge Corona Grid Mesh
1. Blow all foreign matter off the Grids with a blower
brush.
If the blower brush is not effective in cleaning the
Grids, use a soft cloth dampened with alcohol to
clean serious contamination.
NOTE
7. Using a soft cloth dampened with alcohol, wipe the
Housing clean of dirt.
D-33