5. Remove the Solenoid Cover by unhooking its catches
at three places.
6. Unplug the solenoid connector.
7. Remove the harness from the Solenoid Unit clamps at
two places.
8. Remove one screw to remove the Solenoid Unit.
Make the adjustment with
the Lever in contact with
the metal plate.
3.5
±
0.2mm
If the solenoid has been removed from the Solenoid
Unit, make the adjustment shown on the left with the
Solenoid Unit installed in the Exit/Duplex Switching
Unit.
NOTE
9. Remove three screws to remove the Copy Tray Holder.
D-40