3-2. ADJUSTMENT REQUIREMENTS LIST
Adjustment Item Requirements Adjusting Point
Ref.
Page
Max. Exposure Lamp
Voltage
100 to 127V areas: 81 ±1 V
200 to 240V areas: 162 ±2 V
Control panel D-47
Optimum Exposure Setting
in the Manual Exposure
Mode
Kodak Gray Scale:
no image of the 1st step,
faint image of the 2nd step
Control panel D-51
Optimum Exposure Setting
in the Auto Exposure Mode
Control panel D-52
Manual Bypass Table
Reference Position
(100 %) 20 ±2 mm Manual Bypass Table D-55
1st Drawer Reference
Position
(100 %) 20 ±2 mm Drawer Front Panel D-56
2nd Drawer Reference
Position
(100 %) 20 ±2 mm Drawer Front Panel D-56
Full Size Leading Edge
Registration
(100 %) 20 ±1.5 mm Control panel
D-59
Enlargement Leading Edge
Registration
(200 %) 40 ±3 mm Control panel
D-60
Reduction Leading Edge
Registration
(50 %) 10 ±1.5 mm Control panel
D-61
Image Leading Edge Erase
Width
0.5 to 6.5 mm Control panel
D-62
Unexposed Areas/Edge
Erase Lamp Position
Within 4 mm
Adjusting Screw for
Unexposed Areas/Edge
Erase Lamp position
D-64
Adjustment of the Original
Size Detecting Board
Control panel D-67
D-44