MEAN VALUE
CHART FOR 115/120/127V AREAS
104 105 106 107 108 109 110 111 112 113
81.0 60.7 60.3 60.0 59.7 59.2 59.0 58.5 58.2 58.0 57.7
MEAN
VALUE
114 115 116 117 118 119 120 121 122 123
81.0 57.3 57.0 56.8 56.5 56.2 56.0 55.7 55.5 55.2 55.0
MEAN
VALUE
124 125 126 127 128 129 130 131 132 133
81.0 54.7 54.5 54.3 54.2 54.0 53.7 53.5 53.2 53.0 52.8
MEAN
VALUE
134 135 136 137 138 139 140
81.0 52.7 52.5 52.2 52.1 52.0 51.7 51.5
MEAN
VALUE
V
Rms
V
Rms
V
Rms
V
Rms
When using the testers, voltmeters, or multimeters which show only the mean value, not Rms
values, carry out the following procedure.
1. Measure the line voltage.
2. Referring to the Mean Value Chart corresponding to each voltage area, see the figure under the
voltage obtained in step 1.
If the line voltage is 125 V and Rms value is 81 V, for example, the mean value is 54.5 V.
Therefore, it is recommended that the voltage be adjusted so that the mean value is set as close to
54.5 V as possible.