(5) Adjustment of the Aperture Blades
Requirement
There should be no dark or light bands running in the feeding direction on copies produced.
(Adjust to obtain the center image density for all areas.)
Important
If dark and light bands running in the feeding direction occur on copies, make this adjustment
after checking the following.
1) The Drum Charge Corona Wire, Grid Mesh, and Image Transfer Corona Wire are free of dirt.
2) The surfaces of the Mirrors and Lens are free of dirt.
3) The surfaces of the Exposure Lamp and Main Erase Lamp are free of scratches and dirt.
4) The Cleaning Blade is free of waviness.
1. Make a copy under the following control panel setting.
Original : A3 or A4 crosswise,
11" × 17" or 11" × 8-1/2" crosswise
Paper : A3 or A4 crosswise,
11" × 17" or 11" × 8-1/2" crosswise
Magnification
ratio
:100 %
Exposure : Manual (setting convenient for check)
2. Remove the Original Glass.
3. Turn the copy on the Copy Tray around as shown to
reverse the leading and trailing edges and align it with
the Aperture Blades.
4. Adjust to obtain the center image density for all areas
of the copy.
To make the image darker, move the Aperture Blade
toward the Auxiliary Reflector.
To make the image lighter, move the Aperture Blade
away from the Auxiliary Reflector.
NOTE
D-53