C-23: Loop Length Adjustment Mode
Multi-Copy
Key
Setting
Initial
Setting
Multi-Copy
Key
Setting
Initial
Setting
47 −351+1 Loop length
increased
48 −2
Loop length
decreased
52 +2
49 −153+3
50
Standard
(Approx. 7 mm)
∗
C-31: 1-Sided Original Stop Position
Adjustment Mode
C-32: 2-Sided Original Stop Position
Adjustment Mode
C-33: 2-in-1 Original Stop Position
Adjustment Mode
C-34: 2-in-1 Original Distance Adjustment
Mode
Multi-Copy
Key
Setting
Initial
Setting
43
Adjustment amount:
Approx. -7 mm
∗
50 0mm
58 Approx. +8 mm
∼
∼
∼
∼
NOTE: Loop length varies in approx. 0.7 mm
pitch for each step.
NOTE: The amount of adjustment varies in
approx. 1 mm pitch for each step.
C-90: ATDC Detection Level Mode
Multi-Copy
Key
Setting
Initial
Setting
Multi-Copy
Key
Setting
Initial
Setting
48
Level 1
(T/C ratio: 4.0%)
48
Level 4
(T/C ratio: 5.5%)
49
Level 2
(T/C ratio: 4.5%)
49
Level 5
(T/C ratio: 6.0%)
50
Level 3
(T/C ratio: 5.0%)
∗
50
Level 6
(T/C ratio: 6.5%)
S-12