Setting Procedure
(1) With the copier in the state ready to enter a particular Tech. Rep. Mode, press "6" to set the
copier into the Misfeed Counter Mode.
(2) Press the Paper Select Key, and the first misfeed count appears on the Magnification Ratio
Indicator. Press the Paper Select Key to obtain the count of each Misfeed Counter. The
corresponding LED lights up on the Monitor Display when the misfeed count of that particular
location is shown. After all counts have been shown, the copier is then ready to receive a
clear command.
Clearing a Misfeed Counter
(1) Show the count of the Misfeed Counter to be cleared on the Magnification Ratio Indicator.
(2) Press the Clear Key.
Pressing the Stop Key immediately after the Clear Key has been pressed will undo the clear
command.
A malfunction or misfeed at areas other than the Fusing Unit can be reset by
closing the Front Door after the malfunction has been corrected or misfeed cleared.
NOTE
*
If a PF-101 (for Inch Areas) is being used, the misfeed count for PF-101 is shown as the
PF-201 3rd Drawer count. No count is given for PF-201 4th Drawer.
Types of Misfeed Counters
Paper
Select
Key
Type Monitor Display
Magnification
Ratio Indicator
Multi-Copy
Display
ON
Exit
XXX JC
ON
AD-3/PF-1D
entrance/transport
XXX JC
ON AD-3/PF-1D XXX JC
ON ST-101/S-104 XXX JC
ON AF-3/AFR-7 XXX JC
1139S019AB
1139S020AB
1139S021AB
1139S017AB
1139S018AB
S-18