A2: Mirror Full Size Position Correction (When A0 = 50)
•
Corrects the conjugation distance of the Mirror by varying the Mirror’s full size position in 16
steps (1 step = 8 pulses).
Setting
Value
Description Initial Setting
42
49
Correction: +46
Correction: +102
50 Correction: +110
∗
51
57
Correction: +118
Correction: +166
Add -46 to the above correction amount if A0 is set to 49.
Add +46 to the above correction amount if A0 is set to 51.
A3: Feeding-Direction Magnification Adjustment
•
Adjusts the magnification ratio in the feeding direction by varying the scan speed in 16 steps (1
step = 0.5%).
Setting
Value
Description Initial Setting
42
49
Correction: -4
Correction: -0.5
50 Correction: 0
∗
51
57
Correction: +0.5
Correction: +3.5
∼
∼
∼
∼
∼
∼
∼
∼
S-27