FrameMaker Ver.5.5(PC) EP1054/EP1085/EP2030 TROUBLESHOOTING
98.05.15
T- 3 5
✽ Malfunctions Detected by Copiers, Except in Europe
Code Description Detection Timing
Original Size Detecting Board
C0F02 Original size detection
error (Defective CPU)
• Either UN2 is faulty or a communication error
occurs with PWB-A.
• Under normal conditions:
The fixed-cycle pulse signal (Busy) remains
HIGH or LOW for 3 seconds or more.
• When the Power Switch is ON:
The Busy signal remains HIGH or LOW for 5
seconds or more.
C0FE2 Original Size Detecting
Sensor ➋ failure
<Detection Timing>
After having read the output data from PC113 to
PC116, UN2 determines that there is a failure.
<Sensor Layout>
(Metric Areas)
• ➋: PC113, ➌: PC115 (option),
➍: PC114, ➎: PC116 (option)
✽ PC115 and PC116 are standard for Mixed
inch/metric areas.
• A to E: Sensor locations
(Inch Areas)
• ➋: PC113, ➌: PC115 (option),
➍: PC114, ➎: PC116 (option)
C0FE4 Original Size Detecting
Sensor ➌ failure
C0FE6 Original Size Detecting
Sensors ➋ and ➌ failure
C0FE8 Original Size Detecting
Sensor ➍ failure
C0FEA Original Size Detecting
Sensors ➋ and ➍ failure
C0FEC Original Size Detecting
Sensors ➌ and ➍ failure
C0FEE Original Size Detecting
Sensors➋, ➌ and ➍ fail-
ure
C0FF0 Original Size Detecting
Sensor ➎ failure
C0FF2 Original Size Detecting
Sensors ➋ and ➎ failure
C0FF4 Original Size Detecting
Sensors ➌ and ➎ failure
C0FF6 Original Size Detecting
Sensors ➋, ➌ and ➎ fail-
ure
C0FF8 Original Size Detecting
Sensors ➍ and ➎ failure
C0FFA Original Size Detecting
Sensors ➋, ➍ and ➎ fail-
ure
C0FFC Original Size Detecting
Sensors ➌, ➍ and ➎ fail-
ure
C0FFE Original Size Detecting
Sensors ➋, ➌, ➍ and ➎
failure
A
BCD E
➋
➌
A
➍
B
➎
A
BCD E
➋
➌
A
➍
B
➎