WH
Check
and
adjustment
of
release
lock
voltage
and
LED
blink
voltage
MiCheck
(Release
lock
voltage
|
Standard
|
2.46+0.1V
@ILED
blink
voltage
Standard
|
2.56+0.1V
@In
case
of
out
of
standard
above,
adjust
those
as
following
procedure.
MiMeasuring
instruments:
Constant
voltage
D.C
power
source
(MODEL
524B,
E-1,
E-2)
:
Digital
multimeter
(Type
2508,
3476,
2507)
:
Direct
current
tester
WiChecking
procedure
1.
Check
the
current
consumption
at
B
setting
(incl'd
*
indication)
using
measuring
instru-
ments
as
follows.
Fig.
1
|
Ie
©
Camera
|
OC
power
source
(Output
1
|
Shutter
dial
:
B
fe)
Touch
SW
:
ON
Connection
of
:
G---Battery
case
contact
(B)
power
source
(©---Batter
case
base
plate
2.
Measure
the
release
lock
voltage
while
reducing
slowly
the
voltage
of
D.C
power
source
from
3V.
3.
In
case
of
out
of
standard,
replace
R,,
(68-390KQ).
MFig.
2
M@
Checking
high
and
low
shutter
speed
limits
MiMeasuring
instrument
:
Shutter
tester
(Model
S-2101,
FS-1DMN4)
QOHigh
shutter
speed
limit
(shutter
speeds
in
other
than
high
luminance
operation
in
A
mode.)
@
Check
the
shutter
speed
with
the
shutter
dial
set
to
A.
|
Standard
|
0.69~1.38ms
|
(ZLow
shutter
speed
limit
(shutter
speeds
in
other
than
low
luminance
operation
in
A
mode.)
@
Set
the
shutter
dial
to
A.
and
then
check
the
exposure
time
with
light
to
the
receiver
interrupted.
|
Standard
|
Within
5
sec.
|