1. MP21Z will trigger AUTO report function if the Switch status had been changed.
2. Device Reset Locally Notification(Only report when the MP21Z Switch Module has been triggered the RESET TO DEFAULT)
Association group_2: basic set command
When the output of the MP21Z socket is changed, On (0xFF) or Off (0x00). The MP21Z will automatically send out a related
On (0xFF) or Off (0x00) to its associated group.
MP21Z support Over temperature protection,When the temperature is greater than 105 degrees Celsius, the Heat Alarm signal is sent
Notification Type : Heat Alarm 0x04 . Event :Overheat detected 0x02
Restoring Factory Defaults
All Configuration Parameters values and Association information will be restored to factory default settings and excluded from the
When the device is removed from the host, it is returned to the factory settings
MANUAL RESET
---Power off MP21Z
---keep holding the PROG button
---Power on,Press and keep holding the PROG button for no less than 10 seconds.
Remark : All the setting and data will be permanently deleted.
Please use this procedure only when the network primary controller is missing or otherwise inoperable.