Imagestore 750 User Manual Installation
Miranda Technologies Inc. Page 269
Installation
This section of the User Manual provides a step by step description of the
setting up procedures required for integration of Imagestore 750 into a
broadcast system.
Ventilation
Imagestore 750 is ventilated “front to back”. Air enters the unit through the
front, and exhaust air leaves the unit through the rear of the unit and through
slots in the side at the rear.
Note: It is essential that these air ventilation holes in the front, rear
and side-rear of Imagestore 750 unit remain clear of any
obstruction.
Miranda recommends leaving a minimum ½ inch gap above and below the
Imagestore 750 unit in a rack.
Power Requirements
The unit uses a mains supply input circuit that auto-senses whether the
applied AC mains voltage is in the region of 90-132V and 180-264V AC and
responds accordingly. The unit is tolerant of both 50Hz and 60Hz AC
supplies, and under normal conditions, its power consumption will be
approximately 150 watts, dependent on options fitted.
Environment
The Imagestore 750 will tolerate operating temperatures in the range 5°C to
40°C with humidity of between 20 and 80%, non-condensing. The unit is
more tolerant in storage and may be stored at temperatures ranging from