Front Panel Operations Imagestore 750 User Manual
Page 96 Miranda Technologies Inc.
Clean Select
Select Operate, Clean Select.
Clean Select Menu Tree
Operate
Clean Select
Program o/p
SDI A
SDI B
SDI C
SDI D
AB Mix
PGM DVE o/p
PGM DSK1 o/p
PGM DSK2 o/p
PGM DSK3 o/p
This option allows the user to switch the clean feed output to any of the
named signal paths. The Clean output may be used for tapping-off partially
branded video from the Program channel.
Using the front panel joystick arrows (W X) display the clean feed output
source you wish to monitor then press enter.
To go back a level press escape.
Note: The output seen with the PGM DVE output depends on the
current DVE Configuration.