EasyManua.ls Logo

Miranda Kaleido-X16 - Power Supplies

Miranda Kaleido-X16
45 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8
Kaleido-X16 Installation
Monitoring the Temperature of the Kaleido-X16
1
Monitoring the Temperature of the Kaleido-X16
For optimal performance, it is strongly recommended that you operate the Kaleido-X16 multi-viewer in an
environment with an ambient temperature between 0 °C and 40 °C.
There are two factors that could influence airflow inside the frame: altitude and airflow obstruction on the
sides of the unit.
Power Supplies
Power supply for the Kaleido-X16 frame
The Kaleido-X16 frame is powered by dual redundant, current-sharing power supply units (PSUs). The
PSUs are installed and removed from the front of the frame and are hot-swappable, so that a defective
supply may be replaced without removing the Kaleido-X16 frame from service. When facing the front of
the frame, the PSU on the left side is referred to as PSU A and the PSU on the right side is PSU B.
Gen. Status System OK Intrusive self-
diagnostic
finished
Configura-
tion Failed,
Safe Mode
Firmware
Upgrad-
ing
Boot up Diag-
nostic (Ver-
bose switch
on)
Firmware
error
Front cover is
closed
Severity Boot OK Booting Boot error,
Need live-
update
Fatal er-
ror, CALL
TECH SUP-
PORT
N/A N/A No power
IMPORTANT: When measuring the ambient room temperature, take your readings from directly in front of
the Kaleido-X16 frame.
LED LED Status
Green Blinking
green
Red Blinking
red
Yellow Blinking
yellow
Off

Other manuals for Miranda Kaleido-X16