118
Calibrating the Kaleido-X
Multiviewer Output Calibrations
on your purposes, the content provided through the DVI input can be set either as a
background or as a foreground for the layout shown on the monitor wall.
To calibrate the DVI keying mode
1 In the main window, click the System tab, and then click Description/Calibrations on
the second-level tab bar.
A hierarchical list representing the current system appears.
2 In the list, expand the multiviewer whose output heads you wish to calibrate.
3 Expand the appropriate output module.
The expanded module will show the output heads. (Depending on the multiviewer
model, other items may also appear.)
4 Select the head you wish to calibrate.
5Click the Properties tab, and then select the appropriate value from the DVI Input
Keying Mode list.
Notes
The Kaleido-IP and KMV-3901/3911 multiviewers do not support DVI
keying.
Background keying is enabled by default, and should remain enabled
when no actual keying is involved. Enabling the foreground keying mode
when there is no signal at the associated DVI input is not supported.
For more information about using content from the DVI input as
background, refer to
Setting up a Layout for Background Keying from the
DVI Input, on page 211.