2 In the list, expand the multiviewer whose inputs you wish to calibrate.
3 Expand the appropriate input, its ABT element, and then one of the ABTs audio
elements. Select Zero VU.
4Click the Properties tab.
5 Set the reference levels to the appropriate values (in dBFS, and in dBu), using the Zero
VU sliders, under Calibration. Alternatively, type the values directly in the Zero VU
boxes.
6Click Apply to all to apply the chosen Zero VU reference values throughout the system.
Calibrating Dolby VANC Loudness Measurement
To calibrate an audio source
1 In the main window, click the System tab, and then click Description/Calibrations on
the second-level tab bar.
A hierarchical list representing the current system appears.
2 In the list, expand the multiviewer whose inputs you wish to calibrate.
3 Expand the appropriate input, and then click Loudness - dialnorm.
4Click the Properties tab, and then set the appropriate values for your installation.
Note: This section does not apply to the Kaleido-IP or KMV-3901/3911.