127
Kaleido-X
User’s Manual
The default value is Auto which means that the multiviewer will automatically detect
what is present in the signal and use it to report AFD. If more than one AFD type is
present in the signal, and SD AFD source is set to Auto, then the AFD type is selected in
this order: (1) AFD
2016 first, (2) AFD VI, or (3) WSS.
7Click Apply to all to apply the associated setting to all video inputs on your
multiviewer.
Calibrating Detail Enhancement and Dynamic Range
To configure detail enhancement and dynamic range for a video signal
1 In the main window, click the System tab, and then click Description/Calibrations on
the second-level tab bar.
A hierarchical list representing the current system appears.
2 In the list, expand the multiviewer whose inputs you wish to calibrate.
3 Expand the appropriate input, then one of its Video elements.
4Under Video calibrations, click Detail enhancer, and then set the appropriate value
(between 0 and 15) in the Properties tab.
5Click Dynamic range, and then set the appropriate value (either Full range or Video
range) in the Properties tab.
Calibrating Subtitling/Closed Captioning
To configure Teletext/Subtitling page selection
1 In the main window, click the System tab, and then click Description/Calibrations on
the second-level tab bar.
A hierarchical list representing the current system appears.
2 In the list, expand the multiviewer whose inputs you wish to calibrate.
3 Expand the appropriate input, then one of its Video elements.
4Under Teletext & Subtitling Alarms, expand the Page A element, and then click Page
selection.
Note: The KMV-3901/3911 multiviewer does not support detail enhancer
calibrations.

Table of Contents