362
Tally Interface Devices
Kayenne Production Switcher
4 In the port selection area, touch the port you wish to use as the tally contribution port.
5In the Baud Rate / Parity area, touch 115.2k, and None.
This sets the baud rate to 115,200 and the parity to None.
Assuming the required sources and outputs have been defined, this completes the
configuration required on the switcher. The multiviewer system will be able to send
commands to the switcher, and the switcher will respond accordingly. Refer to the Kayenne
Installation and Service Manual for more details.
7
Configuring the Multiviewer
For your multiviewer to receive tally status, source names and output names from a
Kayenne switcher, and to display the switchers contribution on the monitor wall as visual
tally and dynamic text information, you need to configure your multiviewer’s Kayenne
serial tally service, by performing the following tasks in XEdit:
set up the communication parameters for the serial connection;
configure logical sources by assigning input names, output names, and tally status
from the switcher to the logical sources’ text or alarm levels;
assign alarm and text levels from logical sources to layout elements such as UMDs or
alarm monitors.
Establishing Serial Communication Between the Kayenne Switcher and the
Multiviewer
To set up the multiviewer’s communication parameters
1Open XEdit.
2 In the main window, click the System tab, and then click Description/Calibrations on
the second-level tab bar. The main pane displays the System hierarchical list, and the
Tools pane displays the equipment library when the root of the System list is selected.
3Drag the Kayenne production switcher device from the equipment library onto the
root of the System hierarchical list. Alternatively, right-click the list root, and then click
Insert Kayenne on the shortcut menu.
A window appears, prompting you for a device identifier.
4 Type a name for the Kayenne production switcher, and then click OK.
5Click the Interconnects tab.
6 Position the pointer over the multiviewer icon, then click and drag towards the
Kayenne production switcher icon.
A line representing the connection between the multiviewer and the device appears.
7.Manuals and Release Notes for all Grass Valley production switchers are available here:
http://www.grassvalley.com/docs/all_switchers.html#manuals

Table of Contents