363
Kaleido-X
User’s Manual
7 Click the connection line between multiviewer and device.
8In the Properties pane, select the appropriate serial port from the RS-422
communication port list.
9In the Interconnects tab, click the Kayenne production switcher icon.
10 In the Properties pane, set the serial
communications properties for the Kayenne device
as follows:
11 Set the appropriate output numbers to use for tally
calculation, based on your switcher’s configuration.
The current version of the Kaleido-X software supports monitoring of up to 6 tallies
from a Kayenne Video Processor Frame. By default, in XEdit, Tally 1 corresponds to the
Kayenne’s output 1 (which typically carries the Program signal), and Tally 2 corresponds
to the Kayenne’s output 5 (typically the Preview signal). The following table lists the
default output assignments on a Kayenne Video Processor Frame. Refer to the Kayenne
Installation and Service Manual for more details.
8
Baud Rate 115200
Data Bits 8
Parity NONE
Stop bits 1
8.Manuals and Release Notes for all Grass Valley production switchers are available here:
http://www.grassvalley.com/docs/all_switchers.html#manuals
ME A ME B ME C ME D
Output # Signal Output # Signal Output # Signal Output # Signal
1 Pgm A 13 ME1 A 25 ME2 A 37 ME3 A
2 Pgm B 14 ME1 B 26 ME2 B 38 ME3 B