375
Kaleido-X
User’s Manual
Text level selection for the text label in a UMD
8 Click outside the composite to lock it, if applicable.
9Repeat step 4step 8 until you have configured all UMDs that are to display dynamic
text and tally status when this layout is loaded on the monitor wall.
10 On the File menu, click Save.
11 If you are working in offline mode, then you must export the database to your
multiviewer: on the Configure menu, point to Database, and then click Export.
On the monitor wall, you can now load the layout containing the monitors that were
assigned dynamic text and tallies provided by the Zodiak switcher. Input or output names,
as well as tally status from the Zodiak switcher will be visible on the monitor wall. Any
changes made by the switcher’s operator will be immediately reflected on the monitor wall.
Serial Port Test Agent
During a setup, it is sometime not clear if the wiring between the multiviewer and a
peripheral device is correct or if the peripheral device sends the expected data. One can
connect a serial-port test agent as a peripheral device in XEdit, export the database to the
multiviewer, and then read, on a Web page, the data received on the serial port.
To use a serial port test agent
1 Select the Serial port test device in the equipment library and drag it onto the root of
the System hierarchical list. Alternatively, right-click the list root, and then click Insert
Serial port test on the shortcut menu.
2Click the Interconnects tab in the main window.
3 To connect the test device to the multiviewer, click the multiviewer’s icon, or the
devices, and drag the pointer towards the other.
4 Click the test devices icon, and adjust the port settings to match those of the actual
peripheral device you wish to test.
5 Click the connection line between the device and the multiviewer.