410
Administration and Servicing
Assigning an IP Address to Each Device in Your System
2 Referring to Changing the Client PC’s IP Address, on page 400, configure the PC with
the following network settings:
3 Apply power to the Audio Bridge Terminal and make sure it is connected to the same
switch as the PC. If the switch is Power over Ethernet (PoE) enabled, simply connect it to
the unit using an Ethernet cable. If not, PoE mid-span (“inserter”) equipment must be
placed between the switch and the Audio Bridge Terminal.
4 Press the RESET button (located on the right-hand side of the ABT rear panel beside the
ETHERNET/POWER RJ-45 connector) for at least 1 second. The Audio Bridge Terminal
will reboot with the following static network configuration:
5 Using a Web browser on the PC, connect to the ABT using the following address:
10.0.3.190.
The home page of the ABT’s built in Web server is displayed.
6Click Network Configuration (in the navigation pane).
The Network Configuration page is displayed.
7 Change the ABT’s network settings, as necessary, and then click Apply & Reboot.
For more information, please refer to the Audio Bridge Terminal Guide to Installation and
Operation, available on the DVD that shipped with your system, and from Miranda’s support
portal.
DHCP Off
Static IP address 10.0.0.1
Subnet mask 255.255.0.0
Default gateway 10.0.0.1
DHCP OFF
Static IP address 10.0.3.190
Subnet mask 255.255.0.0
Default gateway 10.0.0.1
Note: If you purchased more than one Audio Bridge Terminal unit, keep in
mind that they all ship with the same default static IP address. Make sure to
assign each of them a different static IP address before connecting them to