Configuration
Version 2.7 TX3 Telephone Access System Programming Manual 19
LT-979 Copyright 2018
3. Use the * key to select the number and the telephone (enter) key to confirm
the DTMF code. Valid numbers are 1 to 9, * or #.
Note: Do not select 4 (this is used to refuse entry or disconnect).
Do not use the same number for the main door, auxiliary door, and
call waiting (call waiting works on NSL systems only).
If the Telephone Access System Panel has controller board model
MD-1245, do not select 1, 7, or *.
4. Press the info key to return to the previous menu.
2.7.5 Main Door Timer
The Main Door Timer function defines the length of time that the main door stays
unlocked after the resident opens the main door using the telephone keypad. The
default is 10 seconds.
To set the Main Door Timer
1. Press the arrow key to scroll to “Main Door Timer” and press the telephone
key. The Main Door Timer selection entry appears.
2. Use the up or down keys to select the number of seconds. Valid
programmable time is 1 to 60 seconds.
3. Press the info key to return to the previous menu.
2.7.6 Aux Door Timer
The Auxiliary Door Timer function defines the length of time that the auxiliary
door stays unlocked after the resident opens the auxiliary door using the
telephone keypad. The default is 10 seconds.
Main Door Timer
[ 010 ]