3
Setup type or pulse length of Auxiliary relay: (Default = latch mode)
Type in the following:
Master Code Master Code (chime tone up) *58 00 for latch mode or 001 sec for 1 sec, 002 for 2
sec 999 for 99 sec # to exit programming mode. (Chime tone down)
Activate the incorrect code attempt lock out: (Default = disabled)
(Keypad disables keystrokes for 30 sec. after 5 incorrect code entries or 20 consecutive incorrect
keystrokes.
Type in the following:
Master Code Master Code (chime tone up) *51 # to exit programming mode. (Chime tone down)
Activate the Bypass code option: (Default = Deactivated)
(When the Bypass code is entered the Lock relay latches on until the bypass code is re-entered)
Type in the following:
Master Code Master Code (chime tone up) *52 1 # to exit programming mode. (Chime tone down)
Deactivating the bypass mode option:
Type in the following:
Master code Master code (chime tone up) *52 0 # to exit programming mode. (Chime tone down)
Setup bypass code: (Default = none)
(When the Bypass code is entered the Lock relay latches on until the bypass code is re-entered)
Type in the following:
Master Code Master Code (chime tone up) *54 New unique bypass code # to exit programming
mode. (Chime tone down)
Power down.
Place jumper in the system restore position.
Power up.
Replace jumper in the original position at sound of buzzer tone.
All settings and codes are now back at factory default value.
Default the Keypad to factory default settings:
2
12V/24V
Aux Out
Nc
Com
No
Loc
k Out
(-)
Out
AL
POWER
SUPPLY
1N4004
DOOR RELEASE
BUTTON
NEGATIVE TRIGGER
STROBE / ALARM
DEVICE
+
STRIKE
MAG
+
-
CATHODE
ELECTRIC LOCK
DC
AC/DC
12v-24v