MITS U Series - Auxiliary Heat Delay Wiring Diagram

Default Icon
7 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SIMPLIFIED LOW VOLTAGE WIRING DIAGRAM
MITS AIR “U” SERIES ADD-ON HEAT PUMP
B
B
B
C
CC
C
C
R
R
R
R
R
W
WW
W
W
Y
Y
Y
Y
Y
G
GG
G
G
THERMOSTATTHERMOSTAT
THERMOSTAT
FURNACE
FURNACE
B C
L
L
R
Y2
OUTDOOR UNIT
OUTDOOR UNIT
MODELS
MOX330U-18HFN1-MR0
MOX430U-24HFN1-MR0
MOD30U-30HFN1-MR0
MOD30U-36HFN1-MR0
MOE30U-48HFN1-MR0
MOE30U-60HFN1-MR0
24 volt ac
Time Delay
on “ON”
(Set to 10 Min.)
Notes:
1. is aThermostat HEAT
PUMP type.
2. configuration is used“B”
for the reversing valve.
3. Push reset button after
changing switch to4-2
“ON” and power has
been restored. .
Interface Module H1280-E922
S1 B
C
S2
R
W
Y2
D
L
Y
O
N
1
O
N
1
O
N
1
O
N
1
SW4-1 OFF
SW4-2 ON
SW4-3 OFF
SW4-4 OFF
Switch 4
OUTDOOR UNIT INTERFACE BLOCK
DIP SWITCH 4-2
MUST BE SET
TO “ON”
RESET SWITCH
When resetting switch 4-2, turn off
power to outdoor unit, set switch 4-2 to
“ON”. Restore power and push reset
With Auxiliary Heat Time Delay