α
2 Simple Application Controllers
Function Blocks 6
6 - 73
Setup of the Calculation Function Block directly from the
α
2
Series Controller
1 ) Allocate the input pin to be used for the function block.
2 ) Press the “OK” key with the cursor in the function block.
The function block edit screen is displayed as shown.
3 ) Press the “OK” Key and enter the function block settings using the “ and ” keys. The
Calculate operation [y= ] must be specified.
4 ) While the cursor is flashing, use the and ” keys to select the appropriate character or
constant for your intended calculation. The following items are offered: A, B, C, D, +, -, *, /,
%, ( or )
5 ) DirectSet values, Analog In or FB Value can all be entered for each constant.
6 ) Return to the FBd using the “ESC” key.
Change No
De l e t e FB
B001 :C LA
Se t up FB
[y= ]
B001 :C LA3
Con t an t A
0
[y= ]
B001 :C LA3
A
s
Di rectSet
Ana l og I n
FB Va l ue
B001 :C LA