EasyManua.ls Logo

Mitsubishi Electric CR800-D Series - Robot (system) Status Variables; Consumption Status (Reduction Gear)

Mitsubishi Electric CR800-D Series
194 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Robot (system) status variables 131
M_PMStsGrs: Consumption status (grease)
[Function]
Returns the consumption status of grease of the specified axis.
[Format]
Example) <Numeric variable> = M_PMStsGrs(<Axis number>)
[Terminology]
<Numeric variable> Specify the numeric variable to assign.
<Axis number> Specify the joint axis to get the cumulative rotation count. (1 to 6)
When omitted, 1 is used.
[Sample]
1 M1 = M_PMStsGrs(1) 'The consumption status of the grease for the J1 axis is set in M1.
[Explanation]
(1) Returns the consumption status of the grease of each joint axis of the robot body (mechanism 1).
0 : The remaining time exceeded the warning occurrence remaining time.
1 : The remaining time is less than the warning occurrence remaining time, exceeded 0 [h].
2 : The remaining time is 0 [h] or less.
(2) This variable is read only.
(3) Returns "-1" when the predictive/preventive maintenance function is disabled.
(4) Returns "0" when a nonexistent axis is specified in <Axis number>.
(5) Returns "0" for joint axes that do not require grease replenishing.