Parameter 161
14.2. Consumption degree calculation function
14.2.1. Setting parameters
(*1 Attributes in the table, R: Read only, W: Write only, R/W: Read/write)
Parameter
Parameter
name
Number of
elements
Details explanation
Factory
setting
Attribute
*1)
Warning
remaining
number of days
and operation
time of a day
PMWNGDAY
Integer 2
Specify the warning remaining number
of days and operation time of a day of
the predictive/preventive maintenance
function.
Element 1
Specify the remaining number of days
(remaining recommended maintenance
time) to issue a warning by the
predictive/preventive maintenance
function.
Unit: [day]
Setting range: 0 or higher
Element 2
Specify the operation time of a day used
by the predictive/preventive
maintenance function.
Unit: [h] (time)
Setting range: 1 to 24
* The warning remaining number of
days is calculated by Element 1 x
Element 2.
(30, 16)
R/W
Notification
interval of part
consumption
PMWNGTI
Integer 1
Specify the notification interval of part
consumption of the
predictive/preventive maintenance
function. Specify the interval (hours) to
issue a warning by the
predictive/preventive maintenance
function.
After warning/signal output is reset,
warning does not occur until the
specified hours elapses.
Unit: [h] (time)
Setting range: 1 to 24
6
R/W