EasyManua.ls Logo

Mitsubishi Electric CR800-D Series - Parameter; Data Acquisition: Getting Consumption Degree (Continued)

Mitsubishi Electric CR800-D Series
194 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter 164
Parameter
Parameter
name
Number of
elements
Details explanation
Attribute
*1)
Consumption degree of the
predictive/preventive
maintenance function
(grease)
CSMPMGRS
Real
number 8
Consumption degree of the
predictive/preventive maintenance function
(grease)
(Up to three decimal places)
* "-1" when the predictive/preventive
maintenance function is disabled, and "0"
when the axis does not exist.
R
Consumption degree of the
predictive/preventive
maintenance function
(timing belt)
CSMPMBLT
Real
number 8
Consumption degree of the
predictive/preventive maintenance function
(timing belt)
(Up to three decimal places)
* "-1" when the predictive/preventive
maintenance function is disabled, and "0"
when the axis does not exist.
R
Consumption degree of the
predictive/preventive
maintenance function
(reduction gear)
CSMPMDEC
Real
number 8
Consumption degree of the
predictive/preventive maintenance function
(reduction gear)
(Up to three decimal places)
* "-1" when the predictive/preventive
maintenance function is disabled, and "0"
when the axis does not exist.
R
Consumption degree of the
predictive/preventive
maintenance function
(bearing)
CSMPMBRG
Real
number 8
Consumption degree of the
predictive/preventive maintenance function
(bearing)
(Up to three decimal places)
* "-1" when the predictive/preventive
maintenance function is disabled, and "0"
when the axis does not exist.
R
Consumption degree of the
predictive/preventive
maintenance function (ball
screw/ball spline)
CSMPMBSS
Real
number 8
Consumption degree of the
predictive/preventive maintenance function
(ball screw/ball spline) (Up to three decimal
places)
* "-1" when the predictive/preventive
maintenance function is disabled, and "0"
when the axis does not exist.
R
<Getting remaining time>
Parameter
Parameter
name
Number of
elements
Details explanation
Attribute
*1)
Remaining time of the
predictive/preventive
maintenance function
(mechanism total
(maintenance parts))
RMNPMMNT
Integer 1
Remaining time of the predictive/preventive
maintenance function (mechanism total
(maintenance parts))
* "-1" when the predictive/preventive
maintenance function is disabled.
R
Remaining time of the
predictive/preventive
maintenance function
(servo ON time (at overhaul
implementation))
RMNPMSRV
Integer 1
Remaining time of the predictive/preventive
maintenance function (servo ON time (at
overhaul implementation))
* "-1" when the predictive/preventive
maintenance function is disabled.
R

Table of Contents

Other manuals for Mitsubishi Electric CR800-D Series

Related product manuals